Author: Site Editor Publish Time: 2025-12-09 Origin: Site
In high-rise buildings, door hardware plays a critical role in life safety, fire containment, and evacuation efficiency. Unlike low-rise projects, high-rise buildings face unique challenges such as vertical evacuation, heavy fire doors, pressurized stairwells, and strict certification requirements.

During a fire or emergency, high-rise occupants rely primarily on stairwells rather than elevators. Door hardware must support fast, safe, and obstruction-free vertical evacuation.
• Doors must open easily with minimal force
• Single-action egress is mandatory on escape routes
• Hardware must remain operational under high heat and pressure
• Doors must automatically self-close and latch after use
• Stairwell entrance doors
• Refuge floors
• Transfer corridors
• Service and emergency access doors
Any hardware failure in these zones can severely delay evacuation and compromise life safety.
Fire-rated doors in high-rise buildings are designed to compartmentalize fire and smoke, buying valuable evacuation time.
• Fire-rated mortise locks (CE EN 12209 / UL listed)
• Fire-rated hinges (CE EN 1935 / UL)
• Fire-rated door closers (CE EN 1154 / UL)
• UL-listed panic exit devices where required ( CE EN1125 / UL 10C / UL305)
• Fire-rated door handle (BS EN 1906)
• Fire-rated lock cylinder (BS EN 1303)
Depending on building codes, high-rise fire doors may require:
• 60 minutes
• 90 minutes
• 120–180 minutes
D&D Fire Rated Door Hardware: Click to Certification
CE Door Hardware:
✔️ Door Hinge-BS EN1935 200,000 cycles test, EN1634 Fire Rated 192mins/260mins, EN1670 Corrosion Resistance 240 hours.
✔️ Concealed Hinge-BS EN1935 200,000 cycles test, EN1634 Fire Rated 132mins, EN1670 Corrosion Resistance 48 hours.
✔️ Door Lock-BS EN12209 200,000 cycles test, EN1634 Fire Rated 111mins/260mins, EN1670 Corrosion Resistance 240 hours.
✔️ Door Closer-BS EN1154 500,000 cycles test, EN1634 Fire Rated 120/180mins, EN1670 Corrosion Resistance 96 hours.
✔️ Door Handle-BS EN1906 300,000 cycles test, EN1634 Fire Rated 183/260mins, EN1670 Corrosion Resistance 240 hours.
✔️ Lock Cylinder-BS EN1303 100,000 cycles test, EN1634 Fire Rated 183mins, EN1670 Corrosion Resistance 96 hours.
✔️ Panic Exit Device-BS EN1125 200,000 cycles test, EN1634 Fire Rated 132/240mins, EN1670 Corrosion Resistance 240 hours.
UL Door Hardware:
✔️ Door Hinge-UL/cUL UL 10C Fire Rated 3 Hours, File No.R38013 & ANSI/BHMA Grade1 & Grade 2
✔️ Door Lock-UL 10C Fire Rated 3 Hours,File No.R40901
✔️ Door Closer-UL 10C Fire Rated 3 Hours, File No.R40717
✔️ Fire Exit Hardware- UL 10C Fire Rated 3 Hours, File No.R40486
✔️ Panic Hardware-UL305, File No.SA45817
All components must be tested as a complete door assembly. Mixing certified and non-certified hardware may invalidate the fire rating.

High-rise fire doors are often thicker, wider, and heavier than standard doors, requiring reinforced hinge solutions.
• ANSI Grade 1 heavy-duty hinges
• High load-bearing capacity for steel or composite fire doors
• Ball bearing construction for smooth operation
• Tested for 200,000–2,500,000 cycles or more (ANSI Grade 1 2,500,000 cycles test, ANSI Grade 2 1,500,000 cycles test)
• Stainless steel for corrosion resistance
• Carbon steel with fire-rated coatings for structural strength
Proper hinge selection prevents door sagging, misalignment, and latch failure over time.
Pressurized stairwells are essential in high-rise fire safety systems, preventing smoke infiltration during evacuation.
• Controlled closing under air pressure differences
• Adjustable closing and latching speed
• Reliable operation during power failure
• Compatibility with fire alarm systems (where applicable)
• Heavy-duty surface-mounted door closers
• Concealed fire-rated door closers for architectural designs
• Delayed action closers for accessibility compliance
All stairwell door closers must be CE EN 1154 and/or UL listed to ensure performance under fire conditions.
Certification is not optional in high-rise construction—it is a regulatory and liability requirement.

UL Certification (North America & International Projects)
• UL 10C – Fire resistance of door assemblies
• UL 305 – Panic hardware
• UL-listed hinges, locks, closers, fire exit hardware and accessories
Using CE and UL certified hardware ensures acceptance by inspectors, insurers, and international developers.
Before project approval, confirm that:
• All escape route doors have fire-rated, self-closing hardware
• Hinges are heavy-duty and cycle-tested
• Stairwell doors function properly under pressurizat
Click here for additional details on fire rated door hardware.