Author: Site Editor Publish Time: 2025-11-20 Origin: Site
EN 1125 uses a 14-digit classification, but only 10 main performance categories are graded.
Below is the full list.
Grades: 1 level
| Grade | Meaning |
|---|---|
| 3 | High frequency of use (the only grade allowed for panic devices) |
EN 1125 allows ONLY grade 3 — because panic devices must be high-durability.
Grades: 2 levels
| Grade | Test Cycles |
|---|---|
| 6 | 100,000 cycles |
| 7 | 200,000 cycles |
Grades: 3 levels
| Grade | Door Weight |
|---|---|
| 5 | ≤100 kg |
| 6 | ≤200 kg |
| 7 | >200 kg |
Grades: 2 levels
| Grade | Meaning |
|---|---|
| A | Not suitable for fire/smoke doors |
| B | Suitable for fire/smoke doors |
Grades: ONLY ONE grade
| Grade | Meaning |
|---|---|
| B | Panic safety — mandatory for EN 1125 |
EN1125 requires safety grade B.
(Digit 5 is always B for panic exit devices.)
Grades: 4 levels
| Grade | Salt Spray Hours |
|---|---|
| 0 | Not tested |
| 1 | 24 hours |
| 2 | 96 hours |
| 3 | 240 hours |
| 4 | 480 hours |
Grades: 2 levels
| Grade | Meaning |
|---|---|
| 3 | Standard security |
| 4 | High security |
Grades: 2 levels
| Grade | Meaning |
|---|---|
| 1 | Large projection (>100 mm) |
| 2 | Low projection (≤100 mm) |
Grades: 2 levels
| Grade | Device Type |
|---|---|
| 1 | Push pad (EN 179 style) |
| 2 | Horizontal push bar (EN 1125 panic bar) |
EN 1125 typically uses 2 (push bar).
Grades: 2 levels
| Grade | Door Application |
|---|---|
| A | Single door |
| B | Double door (pair) |
Grades: 2 levels
| Grade | Operation Type |
|---|---|
| A | Push bar |
| B | Touch bar (push across full width) |
| Category | Levels |
|---|---|
| 1. Category of Use | 1 level |
| 2. Durability | 2 levels |
| 3. Door Mass | 3 levels |
| 4. Fire Resistance | 2 levels |
| 5. Safety | 1 level (mandatory) |
| 6. Corrosion Resistance | 4 levels |
| 7. Security | 2 levels |
| 8. Projection | 2 levels |
| 9. Type of Device | 2 levels |
| 10. Door Application | 2 levels |
| 11. Operation Category | 2 levels |
D&D CE Panic Exit Device - BS EN1125 200,000 cycles test, EN1634 Fire Rated 132/240mins, EN1670 Corrosion Resistance 240 hours.